VTG Vertical Turbine Generator
Vertical Turbine Generators
RP’s Vertical Turbine Generators are actually reverse running pumps. When the flow that runs through the pump is reversed, the impeller starts turning in the other direction and the pump operates as a turbine.
Operation limits:
Capacity: up to 6,626 m³/h (29,174 gpm).
Head: to 1,067 m (3,500 ft).
Maximum Pressure: up to 105 bar (1,523 psi).
Temperature: -185 °C to 121 °C (-300 °F to 250 °F).
Applications: Hydroelectric generators, Industrial systems, Water transportation systems, Dams, Reverse osmosis, Oil supply systems, Chemical & Petrochemical processes, Cryogenic closed systems.
OVERVIEW
The motor that drives the pump can work also as a generator; when it’s working as a turbine, it collects the mechanical energy and transforms it into electricity. The VTG is particularly suited to where the head and flow are consistent, and its main purpose is to fill small hydroelectric needs.
The VTG is available for Cryogenic Closed Systems applications.
CHARACTERISTICS
- Multi stage vertical centrifugal pump.
- Enclosed and open impeller available.
- Bearings are product lubricated.
- Different types of turbines for different operation conditions.
- Pump or turbine usage applications.
- Available for sump or closed system applications.
DESIGN FEATURES
- Semi-open runners which are axially adjustable from the operating floor level
- Good efficiency and good choke-flow characteristics
- Discharge may be open into a sump, or into a barrel in a closed system
- API 610 latest edition (VS1) construction available
Note: Depending on materials and size of the turbine; higher pressures or head are possible, please contact Ruhrpumpen.
PERFORMANCE